1.
Sci Rep ; 11(1): 22868, 2021 11 24.
Article in English | MEDLINE | ID: covidwho-1532097

ABSTRACT

Transfer of SARS-CoV-2 from solids to fingers is one step in infection via contaminated solids, and the possibility of infection from this route has driven calls for increased frequency of handwashing during the COVID-19 pandemic. To analyze this route of infection, we measured the percentage of SARS-CoV-2 that was transferred from a solid to an artificial finger. A droplet of SARS-CoV-2 suspension (1 µL) was placed on a solid, and then artificial skin was briefly pressed against the solid with a light force (3 N). Transfer from a variety of solids was detected, and transfer from the non-porous solids, glass, stainless steel, and Teflon, was substantial when the droplet was still wet. The viral titer for the finger was 13-16% or 0.8-0.9 log less than for the input droplet. Transfer still occurred after the droplet evaporated, but was smaller, 3-9%. We found a lower level of transfer from porous solids but did not find a significant effect of solid wettability for non-porous solids.


Subject(s)
COVID-19/transmission , Disease Transmission, Infectious/prevention & control , SARS-CoV-2/metabolism , COVID-19/metabolism , Equipment Contamination/prevention & control , Equipment Contamination/statistics & numerical data , Humans , SARS-CoV-2/pathogenicity , Skin/virology , Viral Load
2.
Crit Care ; 25(1): 403, 2021 11 22.
Article in English | MEDLINE | ID: covidwho-1528689

ABSTRACT

BACKGROUND: Evidence about the impact of the pandemic of COVID-19 on the incidence rates of blood cultures contaminations and bloodstream infections in intensive care units (ICUs) remains scant. The objective of this study was to investigate the nationwide epidemiology of positive blood cultures drawn in ICUs during the first two pandemic waves of COVID-19 in Switzerland. METHODS: We analyzed data on positive blood cultures among ICU patients, prospectively collected through a nationwide surveillance system (ANRESIS), from March 30, 2020, to May 31, 2021, a 14-month timeframe that included a first wave of COVID-19, which affected the French and Italian-speaking regions, an interim period (summer 2020) and a second wave that affected the entire country. We used the number of ICU patient-days provided by the Swiss Federal Office of Public Health as denominator to calculate incidence rates of blood culture contaminations and bloodstream infections (ICU-BSI). Incidence rate ratios comparing the interim period with the second wave were determined by segmented Poisson regression models. RESULTS: A total of 1099 blood culture contaminations and 1616 ICU-BSIs were identified in 52 ICUs during the study. Overall, more episodes of blood culture contaminations and ICU-BSI were observed during the pandemic waves, compared to the interim period. The proportions of blood culture contaminations and ICU-BSI were positively associated with the ICU occupancy rate, which was higher during the COVID-19 waves. During the more representative second wave (versus interim period), we observed an increased incidence of blood culture contaminations (IRR 1.57, 95% CI 1.16-2.12) and ICU-BSI (IRR 1.20, 95% CI 1.03-1.39). CONCLUSIONS: An increase in blood culture contaminations and ICU-BSIs was observed during the second COVID-19 pandemic wave, especially in months when the ICU burden of COVID-19 patients was high.


Subject(s)
Blood Culture , COVID-19/epidemiology , Equipment Contamination/statistics & numerical data , Intensive Care Units/statistics & numerical data , Pandemics , Population Surveillance , Sepsis/epidemiology , Female , Humans , Incidence , Male , Middle Aged , Switzerland/epidemiology
3.
Br J Radiol ; 94(1127): 20210607, 2021 Nov 01.
Article in English | MEDLINE | ID: covidwho-1430509

ABSTRACT

OBJECTIVES: The COVID-19 pandemic has highlighted the importance of aerosol spread of infection. We have conducted a study to detect bacterial contamination of room surfaces and room air during CT colonography and confirm the efficacy of room disinfection procedures carried out between examinations. METHODS: Systematic sampling of the CT examination couch and horizontal surfaces 1 m and 3 m from the couch was performed before and after patient examinations. A 1 m3 sample of room air was obtained during patient examinations. Samples were processed using routine laboratory methods. A case-control study design was used (30 CT colonography and 30 routine body CT scans). RESULTS: Evidence of airborne dissemination of bacteria was detected in >30% of CT colonography examinations and <10% of control examinations (p = 0.01). No pathogenic bacteria were detected in surface samples taken before patient examinations. CONCLUSION: The room disinfection policy in use in our CT department is effective in eliminating pathogenic bacteria from surfaces in the patient environment. CT colonography causes contamination of room air with enteric bacteria in a significant proportion of cases. ADVANCES IN KNOWLEDGE: CT colonography may possibly be an aerosol-generating procedure. Larger-scale investigation is needed to fully evaluate this potential infection risk.


Subject(s)
Air Pollutants/isolation & purification , Colonography, Computed Tomographic/methods , Disinfection/methods , Enterobacteriaceae/isolation & purification , Equipment Contamination/statistics & numerical data , Feces/microbiology , Aerosols , Case-Control Studies , Humans , United Kingdom
4.
BMC Infect Dis ; 21(1): 681, 2021 Jul 13.
Article in English | MEDLINE | ID: covidwho-1317122

ABSTRACT

BACKGROUND: Mobile phones used by healthcare workers (HCWs) are contaminated with bacteria, but the posterior surface of smartphones has rarely been studied. The aim of this study was to compare the prevalence of microbial contamination of touchscreens and posterior surfaces of smartphones owned by HCWs. METHODS: A cross-sectional study of smartphones used by HCWs employed at two intensive care units at a Japanese tertiary care hospital was performed. Bacteria on each surface of the smartphones were isolated separately. The primary outcomes were the prevalence of microbial contamination on each surface of smartphones and associated bacterial species. Fisher's exact test was used to compare dichotomous outcomes. RESULTS: Eighty-four HCWs participated in this study. The touchscreen and posterior surface were contaminated in 27 (32.1%) and 39 (46.4%) smartphones, respectively, indicating that the posterior surface was more frequently contaminated (p = 0.041). Bacillus species and coagulase-negative staphylococci were isolated from each surface of the smartphones. CONCLUSIONS: The posterior surface of a smartphone was more significantly contaminated with bacteria than the touchscreen, regardless of having a cover. Therefore, routine cleaning of the posterior surface of a smartphone is recommended.


Subject(s)
Bacillus/isolation & purification , Equipment Contamination , Health Personnel/statistics & numerical data , Smartphone , Staphylococcus/isolation & purification , Cross Infection/prevention & control , Cross-Sectional Studies , Equipment Contamination/prevention & control , Equipment Contamination/statistics & numerical data , Humans , Infection Control/methods , Intensive Care Units/statistics & numerical data , Japan , Prevalence
5.
Epidemiol Infect ; 149: e67, 2021 03 08.
Article in English | MEDLINE | ID: covidwho-1137722

ABSTRACT

The possibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission by fomites or environmental surfaces has been suggested. It is unclear if SARS-CoV-2 can be detected in outdoor public areas. The objective of the current study was to assess the presence of SARS-CoV-2 in environmental samples collected at public playgrounds and water fountains, in a country with high disease prevalence. Environmental samples were collected from six cities in central Israel. Samples were collected from drinking fountains and high-touch recreational equipment at playgrounds. Sterile pre-moistened swabs were used to collect the samples, put in viral transfer media and transferred to the laboratory. Viral detection was achieved by real-time reverse transcriptase-polymerase chain reaction, targeting four genes. Forty-three samples were collected from playground equipment and 25 samples from water fountains. Two of the 43 (4.6%) samples from playground equipment and one (4%) sample from a drinking fountain tested positive. It is unclear whether the recovery of viral RNA on outdoor surfaces also indicates the possibility of acquiring the virus. Adherence to environmental and personal hygiene in urban settings seems prudent.


Subject(s)
COVID-19/transmission , Equipment Contamination/statistics & numerical data , Parks, Recreational , Play and Playthings , RNA, Viral/analysis , SARS-CoV-2/genetics , COVID-19 Nucleic Acid Testing , Drinking Water , Humans , Israel , Reverse Transcriptase Polymerase Chain Reaction
6.
Antimicrob Resist Infect Control ; 10(1): 51, 2021 03 09.
Article in English | MEDLINE | ID: covidwho-1133610

ABSTRACT

The rapid spread of the coronavirus disease 2019 pandemic urged immense testing capacities as one cornerstone of infection control. Many institutions opened outpatient SARS-CoV-2 test centers to allow large number of tests in comparatively short time frames. With increasing positive test rates, concerns for a possible airborne or droplet contamination of specimens leading to false-positive results were raised. In our experimental series performed in a dedicated SARS-CoV-2 test center, 40 open collection tubes placed for defined time periods in proximity to individuals were found to be SARS-CoV-2 negative. These findings argue against false-positive SARS-CoV-2 results due to droplet or airborne contamination.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Equipment Contamination/statistics & numerical data , Specimen Handling/methods , False Positive Reactions , Humans , Particulate Matter/analysis , Polymerase Chain Reaction , SARS-CoV-2/isolation & purification
7.
PLoS One ; 16(1): e0243554, 2021.
Article in English | MEDLINE | ID: covidwho-1067394

ABSTRACT

With COVID-19 N95 shortages, frontline medical personnel are forced to reuse this disposable-but sophisticated-multilayer respirator. Widely used to decontaminate nonporous surfaces, UV-C light has demonstrated germicidal efficacy on porous, non-planar N95 respirators when all surfaces receive ≥1.0 J/cm2 dose. Of utmost importance across disciplines, translation of empirical evidence to implementation relies upon UV-C measurements frequently confounded by radiometer complexities. To enable rigorous on-respirator measurements, we introduce a photochromic indicator dose quantification technique for: (1) UV-C treatment design and (2) in-process UV-C dose validation. While addressing outstanding indicator limitations of qualitative readout and insufficient dynamic range, our methodology establishes that color-changing dosimetry can achieve the necessary accuracy (>90%), uncertainty (<10%), and UV-C specificity (>95%) required for UV-C dose measurements. In a measurement infeasible with radiometers, we observe a striking ~20× dose variation over N95s within one decontamination system. Furthermore, we adapt consumer electronics for accessible quantitative readout and use optical attenuators to extend indicator dynamic range >10× to quantify doses relevant for N95 decontamination. By transforming photochromic indicators into quantitative dosimeters, we illuminate critical considerations for both photochromic indicators themselves and UV-C decontamination processes.


Subject(s)
Decontamination/methods , N95 Respirators/microbiology , Respiratory Protective Devices/microbiology , COVID-19/prevention & control , Dose-Response Relationship, Radiation , Equipment Contamination/prevention & control , Equipment Contamination/statistics & numerical data , Equipment Reuse/statistics & numerical data , Humans , Indicators and Reagents/radiation effects , Radiometry/methods , SARS-CoV-2/pathogenicity , Sensitivity and Specificity , Ultraviolet Rays , Ventilators, Mechanical/microbiology
8.
J Gastroenterol Hepatol ; 36(7): 1913-1919, 2021 Jul.
Article in English | MEDLINE | ID: covidwho-1052289

ABSTRACT

BACKGROUND AND AIM: During the Coronavirus Disease 2019 pandemic, esophagogastroduodenoscopy (EGD) has been recognized as an aerosol-generating procedure. This study aimed to systematically compare the degree of face shield contamination between endoscopists who performed EGD on patients lying in the left lateral decubitus (LL) and prone positions. METHODS: This is a randomized trial in patients scheduled for EGD between April and June 2020. Eligible 212 patients were randomized with 1:1 allocation. Rapid adenosine triphosphate test was used to determine contamination level using relative light units of greater than 200 as a cutoff value. All eligible patients were randomized to lie in either the LL or prone position during EGD. The primary outcome was the rate of contamination on the endoscopist's face shield. RESULTS: The majority of patients were female (63%), with a mean age of 60 ± 13 years. Baseline characteristics were comparable between the two groups. There was no face shield contamination after EGD in either group. The number of coughs in the LL group was higher than the prone group (1.38 ± 1.8 vs 0.89 ± 1.4, P = 0.03). The mean differences in relative light units on the face shield before and after EGD in the LL and prone groups were 9.9 ± 20.9 and 4.1 ± 6 (P = 0.008), respectively. CONCLUSION: As measured by the adenosine triphosphate test, performing diagnostic EGD does not lead to contamination on the face shield of the endoscopist. However, placing patients in the prone position may further mitigate the risk.


Subject(s)
Endoscopy, Digestive System/methods , Equipment Contamination/statistics & numerical data , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Patient Positioning/methods , Personal Protective Equipment/microbiology , Adult , Aerosols , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
10.
Antimicrob Resist Infect Control ; 10(1): 11, 2021 01 12.
Article in English | MEDLINE | ID: covidwho-1028830

ABSTRACT

BACKGROUND: In intensive care units (ICUs) treating patients with Coronavirus disease 2019 (COVID-19) invasive ventilation poses a high risk for aerosol and droplet formation. Surface contamination of severe acute respiratory syndrome Coronavirus 2 (SARS-CoV-2) or bacteria can result in nosocomial transmission. METHODS: Two tertiary care COVID-19 intensive care units treating 53 patients for 870 patient days were sampled after terminal cleaning and preparation for regular use to treat non-COVID-19 patients. RESULTS: A total of 176 swabs were sampled of defined locations covering both ICUs. No SARS-CoV-2 ribonucleic acid (RNA) was detected. Gram-negative bacterial contamination was mainly linked to sinks and siphons. Skin flora was isolated from most swabbed areas and Enterococcus faecium was detected on two keyboards. CONCLUSIONS: After basic cleaning with standard disinfection measures no remaining SARS-CoV-2 RNA was detected. Bacterial contamination was low and mainly localised in sinks and siphons.


Subject(s)
Bacteria/isolation & purification , COVID-19/therapy , Disinfection/methods , Equipment Contamination/statistics & numerical data , Intensive Care Units/statistics & numerical data , Aerosols/analysis , Bacteria/classification , Bacteria/genetics , Bacteria/growth & development , COVID-19/virology , Cross Infection/microbiology , Cross Infection/prevention & control , Cross Infection/virology , Female , Humans , Male , Middle Aged , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , SARS-CoV-2/physiology , Tertiary Healthcare/statistics & numerical data
11.
PLoS Negl Trop Dis ; 14(10): e0008570, 2020 10.
Article in English | MEDLINE | ID: covidwho-841536

ABSTRACT

Little is known about the SARS-CoV-2 contamination of environmental surfaces and air in non-health care settings among COVID-19 cases. We explored the SARS-CoV-2 contamination of environmental surfaces and air by collecting air and swabbing environmental surfaces among 39 COVID-19 cases in Guangzhou, China. The specimens were tested on RT-PCR. The information collected for COVID-19 cases included basic demographic, clinical severity, symptoms at onset, radiological testing, laboratory testing and hospital admission. A total of 641 environmental surfaces and air specimens were collected among 39 COVID-19 cases before disinfection. Among them, 20 specimens (20/641, 3.1%) were tested positive from 9 COVID-19 cases (9/39, 23.1%), with 5 (5/101, 5.0%) positive specimens from 3 asymptomatic cases, 5 (5/220, 2.3%) from 3 mild cases, and 10 (10/374, 2.7%) from 3 moderate cases. All positive specimens were collected within 3 days after diagnosis, and 10 (10/42, 23.8%) were found in toilet (5 on toilet bowl, 4 on sink/faucet/shower, 1 on floor drain), 4 (4/21, 19.0%) in anteroom (2 on water dispenser/cup/bottle, 1 on chair/table, 1 on TV remote), 1 (1/8, 12.5%) in kitchen (1 on dining-table), 1 (1/18, 5.6%) in bedroom (1 on bed/sheet pillow/bedside table), 1 (1/5, 20.0%) in car (1 on steering wheel/seat/handlebar) and 3 (3/20, 21.4%) on door knobs. Air specimens in room (0/10, 0.0%) and car (0/1, 0.0%) were all negative. SARS-CoV-2 was found on environmental surfaces especially in toilet, and may survive for several days. We provided evidence of potential for SARS-CoV-2 transmission through contamination of environmental surfaces.


Subject(s)
Air Microbiology , Betacoronavirus/isolation & purification , Coronavirus Infections/virology , Equipment Contamination/statistics & numerical data , Pneumonia, Viral/virology , Adolescent , Adult , Aged , Betacoronavirus/classification , Betacoronavirus/genetics , COVID-19 , China/epidemiology , Coronavirus Infections/epidemiology , Environmental Microbiology , Female , Household Articles , Humans , Male , Middle Aged , Pandemics , Pneumonia, Viral/epidemiology , SARS-CoV-2 , Young Adult
12.
BMJ Open ; 10(9): e042045, 2020 09 28.
Article in English | MEDLINE | ID: covidwho-807320

ABSTRACT

BACKGROUND: In a previous randomised controlled trial (RCT) in hospital healthcare workers (HCWs), cloth masks resulted in a higher risk of respiratory infections compared with medical masks. This was the only published RCT of cloth masks at the time of the COVID-19 pandemic. OBJECTIVE: To do a post hoc analysis of unpublished data on mask washing and mask contamination from the original RCT to further understand poor performance of the two-layered cotton cloth mask used by HCWs in that RCT. SETTING: 14 secondary-level/tertiary-level hospitals in Hanoi, Vietnam. PARTICIPANTS: A subgroup of 607 HCWs aged ≥18 years working full time in selected high-risk wards, who used a two-layered cloth mask and were part of a randomised controlled clinical trial comparing medical masks and cloth masks. INTERVENTION: Washing method for cloth masks (self-washing or hospital laundry). A substudy of contamination of a sample of 15 cloth and medical masks was also conducted. OUTCOME MEASURE: Infection rate over 4 weeks of follow up and viral contamination of masks tested by multiplex PCR. RESULTS: Viral contamination with rhinovirus was identified on both used medical and cloth masks. Most HCW (77% of daily washing) self-washed their masks by hand. The risk of infection was more than double among HCW self-washing their masks compared with the hospital laundry (HR 2.04 (95% CI 1.03 to 4.00); p=0.04). There was no significant difference in infection between HCW who wore cloth masks washed in the hospital laundry compared with medical masks (p=0.5). CONCLUSIONS: Using self-reported method of washing, we showed double the risk of infection with seasonal respiratory viruses if masks were self-washed by hand by HCWs. The majority of HCWs in the study reported hand-washing their mask themselves. This could explain the poor performance of two layered cloth masks, if the self-washing was inadequate. Cloth masks washed in the hospital laundry were as protective as medical masks. Both cloth and medical masks were contaminated, but only cloth masks were reused in the study, reiterating the importance of daily washing of reusable cloth masks using proper method. A well-washed cloth mask can be as protective as a medical mask. TRIAL RESGISTRATION NUMBER: ACTRN12610000887077.


Subject(s)
Coronavirus Infections , Disinfection , Equipment Contamination , Infection Control , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Masks , Pandemics , Personnel, Hospital/statistics & numerical data , Pneumonia, Viral , Adult , Betacoronavirus , COVID-19 , Coronavirus Infections/epidemiology , Coronavirus Infections/prevention & control , Coronavirus Infections/transmission , Disinfection/methods , Disinfection/standards , Disinfection/statistics & numerical data , Equipment Contamination/prevention & control , Equipment Contamination/statistics & numerical data , Female , Humans , Infection Control/instrumentation , Infection Control/methods , Infection Control/standards , Male , Masks/classification , Masks/standards , Masks/supply & distribution , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Pandemics/prevention & control , Pneumonia, Viral/epidemiology , Pneumonia, Viral/prevention & control , Pneumonia, Viral/transmission , SARS-CoV-2 , Vietnam/epidemiology
13.
Clin Exp Ophthalmol ; 48(9): 1168-1174, 2020 12.
Article in English | MEDLINE | ID: covidwho-780795

ABSTRACT

IMPORTANCE: Determine phacoemulsification cataract surgery risk in a Covid-19 era. BACKGROUND: SARS-CoV-2 (Covid-19) transmission via microdroplet and aerosol-generating procedures presents risk to medical professionals. As the most common elective surgical procedure performed globally; determining contamination risk from phacoemulsification cataract surgery may guide personal protection equipment use. DESIGN: Pilot study involving phacoemulsification cataract surgery on enucleated porcine eyes by experienced ophthalmologists in an ophthalmic operating theatre. PARTICIPANTS: Two ophthalmic surgical teams. METHODS: Standardized phacoemulsification of porcine eyes by two ophthalmologists accompanied by an assistant. Fluorescein incorporated into phacoemulsification irrigation fluid identifying microdroplets and spatter. Contamination documented using a single-lens reflex camera with a 532 nm narrow bandpass (fluorescein) filter, in-conjunction with a wide-field blue light and flat horizontal laser beam (wavelength 532 nm). Quantitative image analysis using Image-J software. MAIN OUTCOME MEASURES: Microdroplet and spatter contamination from cataract phacoemulsification. RESULTS: With phacoemulsification instruments fully within the eye, spatter contamination was limited to <10 cm. Insertion and removal of the phacoemulsification needle and bimanual irrigation/aspiration, with irrigation active generated spatter on the surgeons' gloves and gown extending to >16 cm below the neckline in surgeon 1 and > 5.5 cm below the neckline of surgeon 2. A small tear in the phacoemulsification irrigation sleeve, presented a worse-case scenario the greatest spatter. No contamination above the surgeons' neckline nor contamination of assistant occurred. CONCLUSIONS AND RELEVANCE: Cataract phacoemulsification generates microdroplets and spatter. Until further studies on SARS-CoV-2 transmission via microdroplets or aerosolisation of ocular fluid are reported, this pilot study only supports standard personal protective equipment.


Subject(s)
COVID-19/epidemiology , Cataract/epidemiology , Disease Transmission, Infectious/statistics & numerical data , Equipment Contamination/statistics & numerical data , Phacoemulsification/adverse effects , SARS-CoV-2 , Comorbidity , Female , Humans , Intraoperative Period , Male , Pilot Projects